Compact DC power for small hypochlorite generator packages
This 60A 16V air-cooled rectifier is a compact DC power option for sodium hypochlorite generators and electrochlorination equipment using a small electrolytic cell. The power supply connects its positive and negative DC terminals to the cell circuit, while the front control section keeps the main electrical readings easy to view during setup and operation.
The 60A 16V rating is a configuration reference, not a universal cell setting. A useful project enquiry includes the target cell voltage and current, operating hours, available AC supply, cable length and the control signals that need to connect to the generator package.
Key functions for compact generator systems
- Adjustable DC output: set output values within the 0–16V and 0–60A rated range.
- Separate digital voltage and current meters: view the two primary output values directly at the front panel.
- Constant-current or constant-voltage operation: select the control mode required by the cell and operating approach.
- Local start/stop control: operate the rectifier at the equipment panel for straightforward packaged installations.
- Running-status indication: see the operating state while commissioning or checking the generator.
- Forced-air cooling: compact air-cooled construction for installations with suitable ventilation clearance.
Configuration reference
| Item | Reference for this configuration |
|---|---|
| DC output voltage | 0–16V adjustable |
| DC output current | 0–60A adjustable |
| Typical process | Sodium hypochlorite generation / electrochlorination |
| Metering | Separate digital voltage and current display |
| Operating mode | Constant current or constant voltage |
| Cooling | Forced air |
| Cabinet layout | Horizontal cabinet |
| Approximate dimensions | 330 × 375 × 160mm |
| Approximate weight | 10kg |
Connection role in an electrolytic generator
The rectifier supplies low-voltage DC energy to the generator cell. The DC cable, terminal hardware, polarity and protective devices should follow the cell and skid wiring layout. If the installation needs a remote start signal, a running indication or an interlock with ancillary equipment, those requirements can be reviewed before the unit is configured.
For higher-current generator packages, compare the 150A 36V sodium hypochlorite generator rectifier. You can also browse the complete sodium hypochlorite generator rectifier range to identify a suitable current and voltage starting point.
What to confirm before ordering
Please provide the cell requirement, desired output range, input power available at site, duty schedule, cable or busbar connection details, cooling conditions and any interface signals. These inputs help match the rectifier connection and control arrangement to the generator package.
Is 60A 16V suitable for every sodium hypochlorite generator?
No. It is a compact configuration reference. The final output depends on the electrolytic cell, feed-water conditions, production target and operating schedule.
What can be read from the separate digital meters?
The front panel provides direct voltage and current readings so operators can check the main DC output values while the system is running.
Can the rectifier be supplied with an interlock or remote signal?
Integration requirements can be reviewed for the generator package. The required signal type, terminals and control sequence should be defined before the configuration is finalised.