40A 300V Automatic cycle reversing electrocatalytic rectifier

Product Parameters

Features
  • Local integrated embedded touchscreen (4.3-inch) control panel
  • Remote (stop/resume) function terminal blocks (on resume, off stop)
  • Automatic cycle reversal, controlled and set by local touchscreen panel: 1-9999 seconds or minutes selectable
  • Employs energy-saving high-voltage reversing switch for non-destructive reversal
  • Output uses high-quality tin-plated copper busbar for corrosion protection
  • Includes RS485 communication function
Commonly Used Water Treatment Power Supply Models (Custom models are available if not listed in the table).
Model Output current A Output voltage V Power KW Input current A Input voltage V Weight (KG) Width W * Length L * Height H
GH10024 100A 24V 2.4 12 220 17 380*400*170
GH100100 100A 100V 10 17 380 40 450*500*225
GH120100 120A 100V 12 20 380 40 450*500*225
GH20015 200A 15V 3 15 220 17 380*400*170
GH20024 200A 24V 4.8 8 380 40 450*500*225
GH20036 200A 36V 7.2 12 380 40 450*500*225
GH20048 200A 48V 9.6 16 380 40 450*500*225
GH200100 200A 100V 20 33 380 130 510*580*920
GH30024 300A 24V 7.2 12 380 40 450*500*225
GH30036 300A 36V 10.8 18 380 40 450*500*225
GH30048 300A 48V 14.4 24 380 95 510*580*690
GH300100 300A 100V 30 50 380 130 510*580*920
GH33030 330A 30V 9.9 16.5 380 40 450*500*225
GH40030 400A 30V 12 20 380 40 450*500*225
GH50024 500A 24V 12 20 380 95 510*580*690
GH50036 500A 36V 18 30 380 95 510*580*690
GH50048 500A 48V 24 40 380 95 510*580*690
GH50012 500A 12V 6 10 380 45 380*400*170
GH60048 600A 48V 28.8 48 380 95 510*580*920
GH100024 1000A 24V 24 40 380 95 510*580*690
GH100036 1000A 36V 36 60 380 130 510*580*920
GH100048 1000A 48V 48 80 380 130 510*580*920
GH100012 1000A 12V 12 20 380 45 480*525*310
GH200024 2000A 24V 48 80 380 130 510*580*920
GH300024 3000A 24V 72 120 380 165 530*600*1200
GH4000100 4000A 100V 400 667 380 195 580*650*1400
GH800036 8000A 36V 288 480 380 235 600*680*1600
GH1000036 10000A 36V 360 600 380 260 800*1350*1510

Overview

This is a smart industrial power supply designed specifically for harsh electrochemical environments. It integrates high-frequency inverter technology with a programmable automatic cycle reversal function, effectively preventing electrode scaling and passivation, significantly improving the stability and efficiency of continuous system operation. It is a revolutionary solution for scaling-prone processes such as electrodialysis and electrolysis.

Structure

The water treatment power supply primarily consists of a rectifier-filter circuit, a full-bridge converter circuit, a high-frequency transformer, a high-frequency rectifier-filter circuit, an auxiliary power circuit, and a main control unit. The main control unit circuit mainly comprises phase loss protection, temperature protection, overload protection, short-circuit protection, and a PWM circuit with PI regulation. The three-phase grid voltage is rectified and filtered after passing through the power switch, yielding a smoothed 520VDC supply for the inverter circuit. The inverter circuit primarily employs high-power MOSFET or IGBT modules to form a full-bridge converter. When the PWM output control signal drives the power modules through isolated drivers, two sets of diagonal transistors conduct alternately. This generates a high-frequency pulse voltage in the primary winding of the high-frequency transformer. The secondary voltage is transformed by the high-frequency transformer, rectified, and then supplies energy to the load.

Features

  1. The power supply can operate in either voltage-regulated current-limited mode or current-regulated voltage-limited mode, with seamless switching between the two states.
  2. DC output voltage regulation accuracy ranges from 50% to 100%. When input voltage fluctuates by 10% or load changes occur, the output voltage remains stable with regulation accuracy ≤0.5%.
  3. Incorporates filtering functionality to prevent interference with instruments during power-up, eliminate grid pollution, and mitigate current inrush phenomena.
  4. Phase Loss Protection: Automatically locks out when any phase is missing from the three-phase AC input. Resumes operation automatically after fault resolution.
  5. Overcurrent Protection: Automatically enters overcurrent shutdown and alarm state when current exceeds rated value.
  6. Short-circuit protection: In case of load short-circuit or internal component short-circuit, the circuit breaker automatically disconnects the power supply.
  7. Over-temperature protection: When abnormal temperatures of semiconductor components (e.g., IGBT, Schottky diodes) reach ≥80°C, the electronic switch on the main control board activates, locking the power supply to effectively protect the unit.